DENVER CYBERKNIFE, LLC
NPI 1902046576
Clinic/Center - Oncology, Radiation in Lone Tree, CO

NPI Status: Active since February 23, 2009

Contact Information

10463 PARK MEADOWS DR
SUITE 114
LONE TREE, CO
ZIP 80124
Phone: (303) 396-1400
Fax: (303) 643-9646

Get Directions Write a Review

  • Organization
  • Clinic/Center
  • Oncology, Radiation

About DENVER CYBERKNIFE, LLC

This page provides the complete NPI Profile along with additional information for Denver Cyberknife, Llc, a provider established in Lone Tree, Colorado operating as a Clinic/center, focusing in oncology, radiation . The healthcare provider is registered in the NPI registry with number 1902046576 assigned on February 2009. The practitioner's primary taxonomy code is 261QX0203X. The provider is registered as an organization and their NPI record was last updated one year ago. The authorized official of this NPI record is James Fagelson Md (Authorized Official)

NPI
1902046576
Provider Name
DENVER CYBERKNIFE, LLC
Entity Type
Organization
Location Address
10463 PARK MEADOWS DR SUITE 114 LONE TREE, CO 80124
Location Phone
(303) 396-1400
Location Fax
(303) 643-9646
Mailing Address
10463 PARK MEADOWS DR SUITE 114 LONE TREE, CO 80124
Mailing Phone
(303) 396-1400
Mailing Fax
(303) 643-9646
Is Sole Proprietor?
No
Is Organization Subpart?
No
Enumeration Date
02-23-2009
Last Update Date
12-26-2024
Code Navigator

Location Map

Specialty - Primary Taxonomy

The NPI enumerator requires providers to submit at least one taxonomy code. A taxonomy code is a unique 10-character code that describes the healthcare provider type, classification, and the area of specialization. There could be only one primary taxonomy code per NPI record. For individual NPIs the license data is associated to the taxonomy code.

Classification

Clinic/Center Oncology, Radiation

Taxonomy Code
261QX0203X
Type
Ambulatory Health Care Facilities

Authorized Official

The authorized official is the designated individual with the legal authority to make changes to the provider’s official NPI record. For organizations, the authorized official must be a general partner, chairman of the board, CEO, CFO or a direct owner holding at least a 5 percent stake in the medical organization.

Authorized Official Name

JAMES FAGELSON MD

Authorized Official Title
AUTHORIZED OFFICIAL
Authorized Official Phone
(303) 733-8848

Areas of Expertise

The following services and procedures, recently provided to Medicare patients, illustrate the range of care this provider offers. This list reflects the variety of services available to all patients visiting the practice and is based on 2022 Medicare dataset. In general, the more frequently a provider treats specific conditions or performs particular procedures, the more experienced they become in addressing similar patient needs. The provider has delivered many of the services listed below to Medicare patients. Please note that this list does not include services provided to patients who are not covered by Medicare.

Calculation of radiation therapy dose

Radiation therapy dose calculation is a process to determine the exact amount of radiation needed to treat a specific area in the body. This calculation helps ensure the treatment is effective while minimizing harm to healthy tissues. It's a key part of planning your radiation therapy.

This service was performed 931 times for 92 patients

Continuing radiation therapy consultation per week

Continuing radiation therapy consultation per week involves regular meetings with your healthcare team. These sessions help monitor your progress, manage side effects, and adjust your treatment plan if necessary. It's a key part of ensuring the effectiveness of your radiation therapy.

This service was performed 202 times for 93 patients

Design and construction of complex radiation treatment device

The design and construction of a complex radiation treatment device is a process where a specialized instrument is created. This device targets harmful cells with high-energy rays to destroy or damage them, while minimizing impact on healthy cells. This aids in treating conditions like cancer.

This service was performed 353 times for 92 patients

High precision radiation therapy planning

High precision radiation therapy planning involves detailed mapping of your body to target cancer cells accurately. Advanced imaging techniques help identify the exact location of the tumor, minimizing harm to healthy tissues. This personalized approach enhances effectiveness and reduces side effects.

This service was performed 94 times for 92 patients

Image-guided robotic linear accelerator-based stereotactic radiosurgery, complete course of therapy in one session or first session of fractionated treatment

Image-guided robotic linear accelerator-based stereotactic radiosurgery is a precise, non-invasive treatment. It uses a machine to deliver high-dose radiation to a specific area in your body, like a tumor, in a single session or across multiple sessions.

This service was performed 79 times for 77 patients

Image-guided robotic linear accelerator-based stereotactic radiosurgery, delivery including collimator changes and custom plugging, fractionated treatment, all lesions, per session, second through fifth sessions, maximum five sessions per course of treatme

This treatment uses high-precision radiation, guided by real-time imaging, to target tumors. A robotic linear accelerator shapes the radiation to match the tumor, reducing harm to healthy tissue. The treatment is spread over 2-5 sessions and is limited to 5 sessions per course.

This service was performed 309 times for 78 patients

Intensity modulated treatment delivery, single or multiple fields/arcs,via narrow spatially and temporally modulated beams, binary, dynamic mlc, per treatment session

Intensity-modulated radiation therapy (IMRT) is a type of cancer treatment. It uses advanced technology to manipulate photon beams of radiation to conform to the shape of a tumor. IMRT allows for the radiation dose to conform more precisely to the three-dimensional shape of the tumor by modulating—or controlling—the intensity of the radiation beam. This can result in better tumor control and less harm to healthy tissue.

This service was performed 540 times for 20 patients

Obtaining data needed to develop the optimal radiation treatment, 3 or more treatment areas or any number of treatment areas where special treatment is involved

This procedure involves collecting necessary data to plan the best radiation treatment. It may cover 3 or more areas or any area requiring special attention. Data collection includes imaging scans and tests to understand the disease's extent and to tailor a precise, effective treatment plan.

This service was performed 15 times for 15 patients

Reviews for DENVER CYBERKNIFE, LLC

There are currently no reviews for this provider. Be the first person to share your experience with this provider by filling out our review form. Your insights are appreciated and will help others make informed decisions.

NPI NPI Number Validation

How NPI Validation Works

The NPI validation process uses the ISO-standard Luhn algorithm, a mathematical "handshake", to ensure that a provider's 10-digit ID is authentic and free of common typing errors.

To verify the NPI 1902046576, we treat the final digit (6) as the Check Digit—the target answer we need to reach. The process begins by taking the first nine digits and adding a constant value of 24, which accounts for the "80840" prefix required for all U.S. health identifiers. We then double every other digit starting from the right and sum the individual digits of those results together. For this specific NPI, that total comes to 54. The final step is to find the difference between that total and the next multiple of ten (60 - 54 = 6).

Digit-by-digit view

Use the first nine digits for the calculation. Starting from the right, double every other digit. The last digit is the check digit and is not part of the calculation.

Pos 1
1
Doubled → 2
Pos 2
9
Unchanged
Pos 3
0
Doubled → 0
Pos 4
2
Unchanged
Pos 5
0
Doubled → 0
Pos 6
4
Unchanged
Pos 7
6
Doubled → 12 → 1 + 2
Pos 8
5
Unchanged
Pos 9
7
Doubled → 14 → 1 + 4
Check
6
Target digit
Regular digit Doubled digit Check digit

Step 1: Double every other digit from the right

Starting with the rightmost digit of the first nine digits, double every other value. If doubling creates a two-digit number, add those digits together.

1 → 2 0 → 0 0 → 0 6 → 12 → 3 7 → 14 → 5

Step 2: Add all digits plus the NPI constant

Add the transformed values, the unchanged digits, and the constant 24.

2 + 9 + 0 + 2 + 0 + 4 + 1 + 2 + 5 + 1 + 4 + 24 = 54

Step 3: Find the amount needed to reach the next multiple of 10

The next multiple of ten after 54 is 60. The difference is the calculated check digit.

60 - 54 = 6
This NPI is valid
The calculated check digit is 6, which matches the last digit of 1902046576.

Other Providers at the Same Location


The following 3 providers are registered at the same or a nearby location.

Clinic/Center (Radiology)
10463 PARK MEADOWS DR, SUITE 114
LONE TREE, CO 80124
Dentist (Pediatric Dentistry)
10463 PARK MEADOWS DR, SUITE 206
LONE TREE, CO 80124
Urology
10463 PARK MEADOWS DR
LONE TREE, CO 80124

Frequently Asked Questions

The NPI number assigned to this healthcare provider is 1902046576, enumerated as an "organization" on February 23, 2009.

The provider is located at 10463 PARK MEADOWS DR SUITE 114 LONE TREE, CO 80124 and the phone number is (303) 396-1400.

Clinic/Center with taxonomy code 261QX0203X and a focus in Oncology, Radiation.