CLACKAMAS RADIATION ONCOLOGY CENTER
NPI 1053649475
Clinic/Center - Oncology, Radiation in Clackamas, OR
NPI Status: Active since November 23, 2009
Contact Information
9280 SE SUNNYBROOK BLVD
SUITE 100
CLACKAMAS, OR
ZIP 97015
Phone: (503) 215-1837
Fax: (503) 215-3687
- Organization
- Clinic/Center
- Oncology, Radiation
- Accepts Insurance
About CLACKAMAS RADIATION ONCOLOGY CENTER
This page provides the complete NPI Profile along with additional information for Clackamas Radiation Oncology Center, a provider established in Clackamas, Oregon operating as a Clinic/center, focusing in oncology, radiation . The healthcare provider is registered in the NPI registry with number 1053649475 assigned on November 2009. The practitioner's primary taxonomy code is 261QX0203X. The provider is registered as an organization and their NPI record was last updated 2 years ago. The authorized official of this NPI record is Alice Wang-chesebro Md (Medical Director)
- NPI
- 1053649475
- Provider Name
- CLACKAMAS RADIATION ONCOLOGY CENTER
- Entity Type
- Organization
- Location Address
- 9280 SE SUNNYBROOK BLVD SUITE 100 CLACKAMAS, OR 97015
- Location Phone
- (503) 215-1837
- Location Fax
- (503) 215-3687
- Mailing Address
- PO BOX 3867 PORTLAND, OR 97208
- Mailing Phone
- (503) 215-8584
- Mailing Fax
- (503) 215-3687
- Is Sole Proprietor?
- No
- Is Organization Subpart?
- No
- Enumeration Date
- 11-23-2009
- Last Update Date
- 10-31-2024
- Code Navigator
Location Map
Specialty - Primary Taxonomy
The NPI enumerator requires providers to submit at least one taxonomy code. A taxonomy code is a unique 10-character code that describes the healthcare provider type, classification, and the area of specialization. There could be only one primary taxonomy code per NPI record. For individual NPIs the license data is associated to the taxonomy code.
- Classification
Clinic/Center Oncology, Radiation
- Taxonomy Code
- 261QX0203X
- Type
- Ambulatory Health Care Facilities
- License State
- OR
Secondary Taxonomies
The provider has reported to the NPI enumerator additional taxonomy codes. Multiple taxonomy codes may represent subspecialties or other areas of specialization the provider maybe licensed to practice.
| No. | Taxonomy Code | Type | Classification / Specialization |
License No. (State) |
|---|---|---|---|---|
| 1 | 261QX0203X | Ambulatory Health Care Facilities | Clinic/Center |
Insurance Plans Accepted
According to publicly available information the provider might be accepting the following health plans from these health insurance companies:
- Connect 1500 Gold - EPO
- Connect 6000 Silver - EPO
- Connect 9800 Bronze - EPO
- HSA Qualified 7500 Bronze - Choice Network - EPO
- HSA-E Qualified 7500 Bronze - Signature Network - EPO
- Providence Oregon Standard Bronze Plan - Choice Network - EPO
- Providence Oregon Standard Bronze Plan - Signature Network - EPO
- Providence Oregon Standard Gold Plan - Choice Network - EPO
- Providence Oregon Standard Gold Plan - Signature Network - EPO
- Providence Oregon Standard Silver Plan - Choice Network - EPO
- Providence Oregon Standard Silver Plan - Signature Network - EPO
*Please verify directly with this provider to make sure your insurance plan is currently accepted.
Areas of Expertise
The following services and procedures, recently provided to Medicare patients, illustrate the range of care this provider offers. This list reflects the variety of services available to all patients visiting the practice and is based on 2022 Medicare dataset. In general, the more frequently a provider treats specific conditions or performs particular procedures, the more experienced they become in addressing similar patient needs. The provider has delivered many of the services listed below to Medicare patients. Please note that this list does not include services provided to patients who are not covered by Medicare.
3d radiation therapy planning
Calculation of radiation therapy dose
Continuing radiation therapy consultation per week
Ct guidance for insertion of radiation therapy fields
Design and construction of complex radiation treatment device
Design and construction of radiation treatment device for high precision radiation therapy
High precision radiation therapy planning
Intensity modulated treatment delivery, single or multiple fields/arcs,via narrow spatially and temporally modulated beams, binary, dynamic mlc, per treatment session
Obtaining data needed to develop the optimal radiation treatment, 1 treatment area
Obtaining data needed to develop the optimal radiation treatment, 3 or more treatment areas or any number of treatment areas where special treatment is involved
Radiation treatment delivery,3 or more separate treatment areas, custom blocking, tangential ports, wedges, rotational beam, compensators, electron beam; 11-19 mev
Radiation treatment delivery,3 or more separate treatment areas, custom blocking, tangential ports, wedges, rotational beam, compensators, electron beam; 6-10 mev
3D radiation therapy planning is a procedure that uses computer imaging to map out the area needing treatment. This ensures the radiation targets the disease precisely, while minimizing exposure to surrounding healthy tissues. It's a key step in preparing for effective radiation therapy.
This service was performed 15 times for 15 patientsRadiation therapy dose calculation is a process to determine the exact amount of radiation needed to treat a specific area in the body. This calculation helps ensure the treatment is effective while minimizing harm to healthy tissues. It's a key part of planning your radiation therapy.
This service was performed 132 times for 44 patientsContinuing radiation therapy consultation per week involves regular meetings with your healthcare team. These sessions help monitor your progress, manage side effects, and adjust your treatment plan if necessary. It's a key part of ensuring the effectiveness of your radiation therapy.
This service was performed 172 times for 52 patientsCT guidance for insertion of radiation therapy fields involves using a CT scan to accurately map the area of your body where radiation will be applied. This ensures the radiation targets only the necessary area, minimizing impact to healthy tissues.
This service was performed 614 times for 35 patientsThe design and construction of a complex radiation treatment device is a process where a specialized instrument is created. This device targets harmful cells with high-energy rays to destroy or damage them, while minimizing impact on healthy cells. This aids in treating conditions like cancer.
This service was performed 122 times for 56 patientsA radiation treatment device is custom-made for each patient to target cancer cells with high precision. It's designed to focus radiation on the tumor, sparing healthy tissue. This process ensures effective therapy while minimizing side effects.
This service was performed 35 times for 27 patientsHigh precision radiation therapy planning involves detailed mapping of your body to target cancer cells accurately. Advanced imaging techniques help identify the exact location of the tumor, minimizing harm to healthy tissues. This personalized approach enhances effectiveness and reduces side effects.
This service was performed 33 times for 28 patientsIntensity-modulated radiation therapy (IMRT) is a type of cancer treatment. It uses advanced technology to manipulate photon beams of radiation to conform to the shape of a tumor. IMRT allows for the radiation dose to conform more precisely to the three-dimensional shape of the tumor by modulating—or controlling—the intensity of the radiation beam. This can result in better tumor control and less harm to healthy tissue.
This service was performed 546 times for 25 patientsThis procedure involves gathering essential information to create the best radiation treatment plan for a specific area. It includes scanning the treatment area and using this data to calculate the precise dose of radiation needed to target the disease effectively, while sparing healthy tissue.
This service was performed 20 times for 20 patientsThis procedure involves collecting necessary data to plan the best radiation treatment. It may cover 3 or more areas or any area requiring special attention. Data collection includes imaging scans and tests to understand the disease's extent and to tailor a precise, effective treatment plan.
This service was performed 30 times for 25 patientsThis procedure involves using high-energy radiation to target and treat disease. It covers 3 or more distinct areas, using custom blocks to protect healthy tissue. Tangential ports, wedges, and rotational beams help direct the radiation. An electron beam of 11-19 million electron volts (mev) is used for deep-seated conditions.
This service was performed 115 times for 16 patientsRadiation therapy involves directing high-energy particles to destroy cancer cells. The technique targets 3 or more areas, using custom blocks for precise focus. Tangential ports, wedges, and rotational beams adjust the radiation's path, while compensators balance radiation dose. Electron beam therapy with 6-10 mev energy is used for deep-seated tumors.
This service was performed 147 times for 14 patientsReviews for CLACKAMAS RADIATION ONCOLOGY CENTER
There are currently no reviews for this provider. Be the first person to share your experience with this provider by filling out our review form. Your insights are appreciated and will help others make informed decisions.
NPI NPI Number Validation
How NPI Validation Works
The NPI validation process uses the ISO-standard Luhn algorithm, a mathematical "handshake", to ensure that a provider's 10-digit ID is authentic and free of common typing errors.
To verify the NPI 1053649475, we treat the final digit (5) as the Check Digit—the target answer we need to reach. The process begins by taking the first nine digits and adding a constant value of 24, which accounts for the "80840" prefix required for all U.S. health identifiers. We then double every other digit starting from the right and sum the individual digits of those results together. For this specific NPI, that total comes to 55. The final step is to find the difference between that total and the next multiple of ten (60 - 55 = 5).
Digit-by-digit view
Use the first nine digits for the calculation. Starting from the right, double every other digit. The last digit is the check digit and is not part of the calculation.
Step 1: Double every other digit from the right
Starting with the rightmost digit of the first nine digits, double every other value. If doubling creates a two-digit number, add those digits together.
Step 2: Add all digits plus the NPI constant
Add the transformed values, the unchanged digits, and the constant 24.
Step 3: Find the amount needed to reach the next multiple of 10
The next multiple of ten after 55 is 60. The difference is the calculated check digit.
Other Providers at the Same Location
The following 4 providers are registered at the same or a nearby location.
CLACKAMAS, OR 97015
CLACKAMAS, OR 97015
CLACKAMAS, OR 97015
CLACKAMAS, OR 97015
Frequently Asked Questions
The NPI number assigned to this healthcare provider is 1053649475, enumerated as an "organization" on November 23, 2009.
The provider is located at 9280 SE SUNNYBROOK BLVD SUITE 100 CLACKAMAS, OR 97015 and the phone number is (503) 215-1837.
Clinic/Center with taxonomy code 261QX0203X and a focus in Oncology, Radiation.
The provider might be accepting Accepts: Providence Health Plan. Please consult your insurance carrier or call the provider to verify.